4. Remove the passenger zone valve bracket nut.

-

To install, tighten to 7 Nm {0.7 kgf-m, 62 in-lbf}.

5. Disconnect the dual-function pressure switch electrical connector and detach the wire harness from the suction accumulator bracket stud.

6. Remove the auxiliary evaporator inlet line fitting nut and disconnect the fitting.

-

Discard the O-ring seal.

-

To install, tighten to 8 Nm {0.8 kgf-m, 71 in-lbf}.

7. Remove the suction accumulator inlet and outlet fitting nuts and disconnect the outlet fitting.

-

Discard the O-ring seal and gasket seal.

-

To install, tighten to 15 Nm {1.5 kgf-m, 133 in-lbf}.

8. Remove the 2 suction accumulator nuts and disconnect the suction accumulator inlet fitting.

-

Discard the O-ring seal and gasket seal.

-

To install, tighten to 7 Nm {0.7 kgf-m, 62 in-lbf}.

9. Remove the suction accumulator.

10. To install, reverse the removal procedure.

-

Install new gasket seals and O-ring seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil. See  See: Service and Repair/Refrigerant Oil Adding.

11. Evacuate, leak test and charge the refrigerant system. See  See: Service and Repair/Air Conditioning (A/C) System Evacuation And Charging.