Tribute 4WD L4-2.5L Hybrid (2009)
![background image](/mazda/tribute_4wd/l4-2.5l_hybrid/Page-1452016.png)
Step 14-Step 16
Pinpoint Test 7: All The Demand Lamps Are Inoperative
PINPOINT TEST 7: ALL THE DEMAND LAMPS ARE INOPERATIVE
Normal Operation
The smart junction box (SJB) energizes the battery saver relay based on inputs from the ignition key position, the door ajar, liftgate ajar and liftgate glass
ajar switches, the remote keyless entry (RKE) transmitter, the keyless entry keypad, and the instrument panel dimmer switch. When the battery saver
relay is energized, voltage is supplied to the demand lamps through circuit (Y/G). The demand lamps are provided ground through circuit (B/GY).
Possible Causes
-
Fuse
-
Wiring, terminals or connectors
-
SJB
Diagnostic Procedure
CAUTION:Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.