mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Intake Manifold|Specifications|Page 1085 > < Intake Manifold|Specifications|Page 1083
Page 3
background image

8. Disconnect the positive crankcase ventilation (PCV) vacuum line.

9. Disconnect the knock sensor (KS) electrical connector.

10. Lower the vehicle.
11. Remove the generator.

NOTE:  Illustration shown with throttle body removed for clarity.

12. Remove the intake manifold.

1. Remove the two nuts and five bolts in the sequence shown.

13. Remove and inspect the intake manifold gaskets.

1. Discard if damaged.

Installation 

NOTE:  Illustration shown with the throttle body removed for clarity.

NOTE:  Install new intake manifold gaskets if damaged.

Intake Manifold|Specifications|Page 1085 > < Intake Manifold|Specifications|Page 1083