mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Control Assembly, HVAC|Description and Operation|Page 5347 > < Condenser HVAC|Testing and Inspection|Page 5343
Page 1
background image

Control Assembly: Description and Operation

CONTROL COMPONENTS

Manual A/C

The manual climate control system heats or cools the vehicle interior depending on the position of the function selector switch and the temperature
selected. The p0sition of the function selector switch determines heating or cooling and air distribution. The temperature control setting determines air
temperature.

The manual climate control system components include:

-

blower motor switch resistor

-

vacuum degas bottle tank

-

climate control assembly

-

blower motor relay

-

A/C compressor clutch relay

-

footwell vent vacuum control motor

-

defrost vacuum control motor panel vent vacuum control motor outside air inlet vacuum control motor

-

temperature blend door control cable 

Control System Inputs

Climate Control Assembly

1. Temperature control switch
2. Function selector switch
3. Blower motor switch

The climate control assembly has three system controls:

-

The A/C heater function selector switch combines a vacuum selector valve with two electrical switches to supply battery positive voltage (B+) to
the A/C clutch circuit and the blower motor control circuit. 

-

The temperature selection is accomplished through cable-controlled positioning of the temperature blend door located in the heater core housing.

-

The blower motor switch controls the blower motor speed by adding or bypassing resistors in the heater blower motor switch resistor.

Control System Outputs 

Blower Motor Switch Resistor

The four-speed operation of the blower motor is achieved through the blower motor switch resistor and contains a thermal limiter which is used as a
temperature protecting fuse. The assembly is located on the passenger-side on the evaporator core housing behind the glove compartment.

Control Assembly, HVAC|Description and Operation|Page 5347 > < Condenser HVAC|Testing and Inspection|Page 5343