Water Pump - Drainage Pipe Retrofitting Procedure|Page 2104 > < Water Pump - Drainage Pipe Retrofitting Procedure|Page 2102
Page 9
background image

3.

Apply sealant/locker to fitting (arrow, Figure 13) and tap it into the lower vent bore of the coolant pump with a suitable mandrel.

4.

Push the drainage pipe over the fitting.

5.

Attach the drainage pipe (1, Figure 14) with the clamp (2) to the generator/fan bracket (4) with M8 x 16 bolt (3).

Tightening torque:
M8 x 16 generator/fan bracket bolt 22 Nm

6.

Attach the drainage pipe (1, Figure 15) at the lower oil pan with the bracket (2) and position correctly.