mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Center Nozzle Flaps|Page 4702 > < Center Nozzle Flaps|Page 4700
Page 8
background image

7. Install angle bracket (72) and supports (70 and 71).
8. Plug on vacuum line (arrow) red/yellow for vacuum element of legroom flaps.
9. Plug 2-pole coupler to temperature sensor (6).

10. Connect electric lines, terminal 58d, to line connector.

Use Of "Wedge"

11. Install instrument panel,for this purpose keep defroster nozzle flaps closed by means of a wedge.
12. Install center console.

Center Nozzle Flaps|Page 4702 > < Center Nozzle Flaps|Page 4700