mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Control Assembly, HVAC|Service and Repair > < Interior - Interior Damage From Scent Dispensers|Page 4868
Page 6
background image

-

Independent of temperature dial adjustment, max. heated air will be routed to windshield and side nozzles.

-

The recirculating pump is always running along and the refrigerant compressor is switched on at outside temperatures above + 2°C. If, with the
ignition switched on, function selection "a" or "b" is pushed, followed by switching to "c" or "d", the system remains in operation also below 33°C
coolant temperature.

Blower Switch (5)

-

The blower operates in 6 stages.

-

At function selection "b", "c" and "d" the air volume can be set as required.

Switch:

Air Volume:

Blower Stage:

f (top)

max.

6 (12 V)

h (bottom)

min.

1 (4 V)

g (center)

automatic

2-5 (5-10 V)

-

During "AUTOM" operation in functions "b, c and d" the blower will start in 2nd blower stage after the system has been switched on with a delay
of approx. 10 seconds, and remains there for approx. 10 seconds. If required, the blower will switch up to 5th blower stage.

Control Assembly, HVAC|Service and Repair > < Interior - Interior Damage From Scent Dispensers|Page 4868