380SL (107.045) V8-3.8L (116.960) (1982)
-
Independent of temperature dial adjustment, max. heated air will be routed to windshield and side nozzles.
-
The recirculating pump is always running along and the refrigerant compressor is switched on at outside temperatures above + 2°C. If, with the
ignition switched on, function selection "a" or "b" is pushed, followed by switching to "c" or "d", the system remains in operation also below 33°C
coolant temperature.
Blower Switch (5)
-
The blower operates in 6 stages.
-
At function selection "b", "c" and "d" the air volume can be set as required.
Switch:
Air Volume:
Blower Stage:
f (top)
max.
6 (12 V)
h (bottom)
min.
1 (4 V)
g (center)
automatic
2-5 (5-10 V)
-
During "AUTOM" operation in functions "b, c and d" the blower will start in 2nd blower stage after the system has been switched on with a delay