Refrigerant: All Technical Service Bulletins
A/C - Fluorescent Dye Leak Testing

Date: September 24, 2007

Order No.: P-B-83.00/97a

Supersedes: P-B-83.00/97 dated May 16, 2007

Group: 83

Revision History

Revision

Date

Purpose

a

9/24/07

Updated to Include Diagnostic Tree Information

-

5/16/07

Initial issue

SUBJECT: 
All Passenger Models

Air Conditioning Not Cooling / Leak Test Using Fluorescent Dye

If you receive customer reports in the above model vehicles of the air conditioning not cooling, temperature fluctuations or noisy compressor operation,
the cause could be low refrigerant level. Refer to the applicable diagnostic tree in the Vehicle Heating, Ventilation, Air Conditioning (HVAC) Manual
found on STAR TekInfo --> EDAC --> Non EDAC Guides. The refrigeration system should be checked for leakage using fluorescent dye as per the
instructions supplied with the leak detection equipment. Please refer to the MBUSA Standard Service Equipment Program (SSEP) catalog
(1-888-458-4040).

Note:

In order to ensure compatibility with all components and materials in the AC system the only approved tracer dye additive to be used is manufactured
by Spectronics Corp. /Tracer Products. If other products are used, warranty submissions could be subject to debit.