mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Fluid Pump, A/T|Description and Operation|Page 3479 > < Fluid Pump, A/T|Description and Operation
Page 2
background image

Primary pump

24   Primary pump check valve
64   Lubricating pressure
66   Secondary pump shaft valve
67   check valve
70   Primary pump
72   check valve
73   Centrifugal
74   Drive for governor
75   Secondary pump
76   Secondary pump cutoff piston
77   Oil filter

A  Working pressure

SR  Lubricating pressure
B2  Connection to shift side B2
RA   Excess pumped oil flow back through nozzle (D) of working pressure control valve into suction passage of primary pump

D  Nozzle

a,b,  Restrictions

c,d,e 

Secondary pump drive 

g  Compression spring
o  Oil sump outlet 

The primary pump (70) (internal gear pump or crescent moon pump) is housed in the front transmission cover. It is driven by the engine through
the drive flange of the torque converter.
The primary Pump (70) operates so long as the engine is turning and supplies pressurized oil to the entire hydraulic system.
The drive (f) of the secondary pump (75) is switched off by the cut-off piston (76) by means of the pressure Of the primary pump (70).

Fluid Pump, A/T|Description and Operation|Page 3479 > < Fluid Pump, A/T|Description and Operation