mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

AR83.10-P-2001P Remove/Install Actuator For Fresh and Recirculated Air Flaps|Page 13219 > < AR83.10-P-2001P Remove/Install Actuator For Fresh and Recirculated Air Flaps|Page 13217
Page 6
background image

11

Perform basic programming.

AR83.10-P-2004P Remove/Install Actuator For Left Defroster Vent Flap

AR83.10-P-2004P Remove/Install Actuator For Left Defroster Vent Flap

- with CODE (581) Comfort automatic air conditioning

Shown on Model 203.0

DANGER:

-

Risk of explosion from electrolytic gas. Risk of poisoning and caustic burns from swallowing battery electrolyte. Injury hazard and
danger of burning skin and eyes when handling battery acid or handling damaged lead-acid batteries

-

No fire, sparks, naked flames or smoking.

-

Wear acid protection gloves, clothes and goggles. Pour battery electrolyte only into suitable and appropriately marked containers.

1

Disconnect ground cable of battery

2

Remove instrument panel

3

Unscrew screws (1)

NOTE:  Three screws.

-

See "Special Tools" given below.

4

Remove left defroster flap actuator motor (M2/8) from AC housing

5

Disconnect connector (3) from left defroster flap actuator motor (M2/8)

6

Install in the reverse order

7

Synchronize left defroster flap actuator motor (M2/8).

Special Tools

Torx bit set, P/N# 000 559 01 10 00

AR83.10-P-2005P Remove/Install Actuator For Right Defroster Vent Flap

AR83.10-P-2005P Remove/Install Actuator For Right Defroster Vent Flap

- with CODE (581) Comfort automatic air conditioning