mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

AR54.10-P-0001Z Initial Filling of Battery|Page 7239 > < AR54.10-P-0001Z Initial Filling of Battery|Page 7237
Page 5
background image

4

Code radio
-

Becker 2000

-

MB model 202

5

Set time at instrument cluster

NOTE:  If necessary set time at stationary heater timer.

Notes on Battery

CAUTION:

-

Do not store lead-acid batteries for extended periods of time in a place where they are exposed to direct sunlight.

-

Always store lead-acid batteries horizontally to prevent acid from escaping; do not tilt them when they are being transported.

-

Discharged or faulty lead-acid batteries can freeze up; therefore, ensure that they are stored at temperatures above freezing level.

-

Do not place any tools or other electrically conductive objects on a lead-acid battery (risk of short-circuit!).

-

Avoid mixing up positive and negative poles and avoid short-circuits.

-

Before removing or installing a lead-acid battery, switch off all electrical consumers where possible, and switch off the engine, so as to
minimize the possibility of creating sparks.

-

Always disconnect the negative pole first; always connect the positive pole first.

-

Do not switch on battery chargers until they have been connected to the battery poles; switch them off before disconnecting.

-

Only charge lead-acid batteries with direct current. For the charging current we recommend 10% of capacity for normal charging and
50% of capacity for rapid charging.

-

During rapid charging it must be insured that the casing of the lead-acid battery does not warm up excessively (< 55 °C).

-

Lead-acid batteries should be kept clean and dry as far as possible.

-

It is advisable to grease the poles lightly with battery pole grease.

-

Lead-acid batteries should not be stored for extended periods without being recharged.

-

If a lead-acid battery is to remain in a vehicle which is not in use for an extended period, the negative terminal clamp should be
disconnected.

Treatment of Battery When Laying Up Vehicle

Treatment of battery when laying up vehicle

Removing, Installing

DANGER:  Risk of explosion from electrolytic gas. Risk of poisoning and caustic burns from swallowing battery electrolyte. Risk of injury with
caustic burns to eyes and skin from battery electrolyte or from handling damaged lead-acid batteries

-

No fire, sparks, naked flames or smoking.

-

Wear acid-resistant gloves, clothing and eye protection. Pour battery electrolyte only into suitable and appropriately marked containers

1.1 Remove rear seat
1.2 Fold rear seat cushion forwards and remove battery compartment cover
1.3 Flip up trunk luggage cover
1.4 Remove cargo space cover
1.5 Open battery cover in passenger-side footwell
1.6 Open engine hood and raise to vertical position
1.7 Remove battery cover in right-hand side of trunk
2

Check battery

NOTE:  Determine findings, if necessary Charge battery

3

Disconnect/connect ground cable on battery

NOTE:  Discharge of battery by quiescent current consumers (clock etc.) is prevented.

4

Charge battery

NOTE:  Every 4 weeks. On no account leave battery in discharged state otherwise sulfate deposits will form on the plates. Plates with sulfate
deposits indicate initial damage to the battery and result in premature failure.

5

Install in the reverse order

AR54.10-P-1129-03A Reduce Increased Voltage After Charging Process

AR54.10-P-0001Z Initial Filling of Battery|Page 7239 > < AR54.10-P-0001Z Initial Filling of Battery|Page 7237