Keyless Entry Module: Description and Operation
IR DAS X Control Module

The purpose of the IR DAS control module is described below:

a)

Infrared remote control for central locking
-

Receive and evaluate signals from lock switches 1 and 2 from infrared remote control (RCL) module, not model 129

After recognition of valid IR Signal
-

Actuation of

- Central locking (CL), not model 129
- Anti-theft alarm (ATA), not model 129
- Convenience feature (CF), not model 129
- Remote trunk release (RTR), only models 140 and 202/210 sedan

-

Read in and evaluate signals from mechanical lock switches (SN1-unlock, SN2-lock), not model 129.

b)

Drive authorization stage X
-

Control of transponder coil on ignition/starter switch

-

Read in and evaluate transponder signal

-

Release engine control module via CAN when transponder code is valid

The IR DAS control module (N54/1) evaluates the transponder data received and, when valid, releases the engine control via the CAN bus.