Component Identification

GF83.10-P-2180-01R Air Flap Actuator Motor, Lateral Nozzle, Function

GF83.10-P-2180-01R Air Flap Actuator Motor, Lateral Nozzle, Function

- with CODE (581) Automatic air conditioning

Function

Depending upon the desired air outlet temperature at the lateral nozzle, the actuator motors for the air flap, left and right lateral nozzles (M16/25) and
(M16/26) are controlled via the A/C databus.

Control ensues using the AAC pushbutton control module (N22)
Defrost function

Lateral nozzle air flaps closed
REST function

Lateral nozzle air flaps closed
System switched off

Lateral nozzle air flaps remain in the previously applied setting

Automatic air-flap control for the lateral nozzles (AUTO button retracted, tip switches for warm and cold not pressed)

Depending upon the following variables, the air flaps are opened by the lateral nozzle actuator motors linearly up to 100 %.

^

Blending air flap setting

^

Coolant temperature

^

Evaporator temperature

^

Footwell flap position