SL 500 (230.475) V8-5.0L (113.963) (2004)
Component Identification
GF83.10-P-2180-01R Air Flap Actuator Motor, Lateral Nozzle, Function
GF83.10-P-2180-01R Air Flap Actuator Motor, Lateral Nozzle, Function
- with CODE (581) Automatic air conditioning
Function
Depending upon the desired air outlet temperature at the lateral nozzle, the actuator motors for the air flap, left and right lateral nozzles (M16/25) and
(M16/26) are controlled via the A/C databus.
Control ensues using the AAC pushbutton control module (N22)
Defrost function
Lateral nozzle air flaps closed
REST function
Lateral nozzle air flaps closed
System switched off
Lateral nozzle air flaps remain in the previously applied setting
Automatic air-flap control for the lateral nozzles (AUTO button retracted, tip switches for warm and cold not pressed)
Depending upon the following variables, the air flaps are opened by the lateral nozzle actuator motors linearly up to 100 %.
^
Blending air flap setting
^
Coolant temperature
^
Evaporator temperature
^
Footwell flap position