mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Suspension - New Alignment Tools and Procedures|Page 1187 > < Suspension - New Alignment Tools and Procedures
Page 2
background image

Electronic data transfer and charging station The electronic data transfer and charging station (EDTCS, Figure 1) allows for direct communication
between the electronic level gauge (ELG) and a DBAG/MBNA approved alignment machine. The ELG is placed directly on the EDTCS and is
connected to the alignment machine via the RS 232 interface. The EDTCS should be mounted according to the alignment machine manufacturers
recommendations to prevent damage to the unit.

Measuring Equipment

The tool consists of an easy to use electronic level gauge (Figure 2) with display (086) and a precision inclinometer (086a), which uses a electronic
version of a bubble scale.

The contours of the inclinometer (086a) were designed in such a way that it can be used to determine vehicle ride height on both front and rear axles.

Application example on front axle

To determine the inclination of the lower control arm on the front axle, an adapter plate (086b) is required, which will define a mounting surface on
which to position the inclinometer (086a).

a)

Insert and align the adapter plate (086b) (note alignment marks on adapter plate) into the opening of the left front lower control arm (Figure 3).
Contact surfaces must be clean.

Suspension - New Alignment Tools and Procedures|Page 1187 > < Suspension - New Alignment Tools and Procedures