mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 3270 > < Initial Inspection and Diagnostic Overview|Page 3268
Page 138
background image

CONNECT the negative battery cable. GO to AE52. 

No

GO to AE40.

-------------------------------------------------
AE40 CHECK THE HS-CAN (+) AND HS-CAN (-) CIRCUITS FOR A SHORT TO GROUND WITH THE BECM DISCONNECTED

 

-

Disconnect: Battery Energy Control Module (BECM) C4237a .

-

Measure the resistance between the DLC C251-6, circuit VDB04 (WH/BU), harness side and ground; and between the DLC C251-14, circuit
VDB05 (WH), harness side and ground.

-

Are the resistances greater than 1,000 ohms?

Yes

CONNECT the negative battery cable. GO to AE53. 

No

GO to AE41.

-------------------------------------------------
AE41 CHECK THE HS-CAN (+) AND HS-CAN (-) CIRCUITS FOR A SHORT TO GROUND WITH THE DC/DC DISCONNECTED

 

-

Disconnect: DC/DC C1457d .

-

Measure the resistance between the DLC C251-6, circuit VDB04 (WH/BU), harness side and ground; and between the DLC C251-14, circuit
VDB05 (WH), harness side and ground.

-

Are the resistances greater than 1,000 ohms?

Yes

CONNECT the negative battery cable. GO to AE54. 

No

REPAIR the circuits. CONNECT all modules. CONNECT the negative battery cable. CLEAR the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
AE42 CHECK FOR CORRECT PCM OPERATION

 

-

Disconnect all the PCM connectors.

-

Check for:
-

corrosion

-

damaged pins

Initial Inspection and Diagnostic Overview|Page 3270 > < Initial Inspection and Diagnostic Overview|Page 3268