Montego AWD V6-3.0L VIN 1 (2005)
E6
Normal Operation
Under normal operation, ground for the ajar switches are provided through circuit 1205 (BK). When any door, liftgate or decklid is ajar, ground to the
smart junction box (SJB) is interrupted. The SJB provides voltage to the individual lamps through circuit 53 (BK/LB). When any door, liftgate or
decklid is closed, ground is provided to the SJB through the circuits below.
Possible Causes
-
LH front door ajar switch circuit 1312 (LG/BK)
-
RH front door ajar switch circuit 1314 (YE/LG)
-
LH rear door ajar switch circuit 1742 (VT/LG)
-
RH rear door ajar switch circuit 1754 (RD)
-
Liftgate ajar switch circuit 700 (WH/VT)
-
Decklid ajar switch circuit 700 (WH/VT)
Test F: The Interior Lamps Do Not Turn On With One Door Open
PINPOINT TEST F: THE INTERIOR LAMPS DO NOT TURN ON WITH ONE DOOR OPEN
F1-F3