mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 10556 > < Initial Inspection and Diagnostic Overview|Page 10554
Page 18
background image

F3-F4

Normal Operation

Under normal operation, ground for the ajar switches is provided through circuit 1205 (BK). When any door, liftgate or decklid is ajar, ground to the
smart junction box (SJB) is interrupted. The SJB provides voltage to the individual lamps through circuit 53 (BK/LB). When any door, liftgate or
decklid is closed ground is provided to the SJB through the circuits below.
-

LH front door ajar switch circuit 1312 (LG/BK).

-

RH front door ajar switch circuit 1314 (YE/LG).

-

LH rear door ajar switch circuit 1742 (VT/LG).

-

RH rear door ajar switch circuit 1754 (RD).

-

Liftgate ajar switch circuit 700 (WH/VT).

-

Decklid ajar switch circuit 700 (WH/VT).

Possible Causes

-

A short to ground in circuits 1312 (LG/BK), 1314 (YE/LG), 1742 (VT/LG), 1754 (RD) or 700 (WH/VT)

-

Ajar switch(es)

-

SJB

Test G: The Demand Lighting Is Inoperative

PINPOINT TEST G: THE DEMAND LIGHTING IS INOPERATIVE

Initial Inspection and Diagnostic Overview|Page 10556 > < Initial Inspection and Diagnostic Overview|Page 10554