Sable V6-183 3.0L DOHC VIN S MFI (1997)
Orifice Tube: Description and Operation
NOTE: The A/C evaporator core orifice should be replaced whenever an A/C compressor is replaced.
The A/C evaporator core orifice has the following characteristics:
^
is color-coded orange
^
has a diameter of 1.46 mm (0.058 inch)
^
is located in the condenser to evaporator tube
^
has filter screens located on the inlet and outlet ends of the tube body
The A/C evaporator core orifice is the restriction in the refrigerant circuit that creates the pressure drop necessary for cooling by metering the flow of
liquid refrigerant into the A/C evaporator core, which reduces the pressure.
Operation is as follows:
^
The temperature of the A/C evaporator core is controlled by sensing the pressure within the A/C evaporator core with the A/C cycling switch.
^
The A/C cycling switch controls compressor operation as necessary to maintain the pressure in the A/C evaporator core within specified limits.
^
The inlet filter screen acts as a strainer for the liquid refrigerant flowing through the A/C evaporator core orifice.
^
O-rings on the A/C evaporator core orifice prevent the high-pressure liquid refrigerant from bypassing the A/C evaporator core orifice.
^
Adjustment or services cannot be made to the A/C evaporator core orifice assembly. It must be replaced as a unit.