Voltage Regulator: Description and Operation

The Voltage Regulator (VR):

^

adjusts the generator field current to increase or decrease generator output current.

^

Sets the generator output voltage.

^

Turns the generator warning indicator on when a problem is detected in the charging system or associated wiring.

The generator output voltage will vary with temperature. The output voltage is typically higher in the winter (cold) and lower in the summer (hot).

The voltage regulator will turn the generator warning indicator on for the following conditions:

^

Ignition switch in the RUN position with the engine not running. This is the lamp prove-out (does not indicate a problem with the charging system)

^

Open in the A circuit

^

Inoperative Generator (GEN)

^

Generator output voltage too high

With the system functioning normally:

^

The generator output current is determined by the voltage of the A circuit (battery-sense voltage).

^

The A circuit voltage is compared to a set voltage internal to the voltage regulator. The voltage regulator controls the generator field current to
maintain proper generator output.

^

The set voltage varies with temperature and is typically higher in the winter than summer, allowing for better battery charging.

The generator warning indicator comes on when a problem is detected in the:

^

Generator.

^

Voltage regulator.

^

Associated wiring.