10. Install new O-ring in groove in outer vane support. Then, install metal O-ring retainer.

11. Install outer vane support retaining pin.

CAUTION:  Pin must not be pushed through the pump body; it should be flush with valve body side of pump to prevent component interference.

12. Install bore ring spring between case and tab on pump bore ring by compressing spring into pump housing.

CAUTION:
^

Be sure this area is well cleaned - it is a hidden debris trap; flow from pump goes into manual valve circuit, then into EPC circuit. Pump
pressure at this point is high, and any contamination not cleaned will be pumped throughout the transaxle on first operation.

^

Do not damage machined surfaces.