Torque Converter|Flow of Diagnosis|Page 7530 > < Torque Converter|Flow of Diagnosis|Page 7528
Page 3
background image

3. Install the torque converter into a press with flywheel studs facing up.
4. Apply enough pressure from the press to seal the tool into the hub of the torque converter.

5. Connect air hose to the tool, apply maximum 80 psi. 

6. With air pressure applied to the torque converter, inspect for leaks at the seams, studs and pilot hub. A soapy water solution may be used in these

areas to aid in diagnosis. If leaks are present in these areas, replacement of the torque converter is necessary.

Torque Converter|Flow of Diagnosis|Page 7530 > < Torque Converter|Flow of Diagnosis|Page 7528