REMOVAL

1. Recover the refrigerant.

2. Remove the two bolts and remove the roll restrictor.

3. Remove the bolts and position aside the roll restrictor bracket.

4. Remove the nut and the A/C hose support bracket.
5. Remove the degas bottle.
6. Disconnect the suction accumulator spring lock coupling. Remove and discard the O-ring seal.

-

During installation, install a new O-ring seal lubricated with PAG Refrigerant Compressor Oil (R-134a Systems) F7AZ-19589-DA (Motorcraft
YN-12-C), or equivalent meeting Ford specification WSH-M1C231-B.