7. Disconnect the A/C cycling switch electrical connector.

8. Disconnect the suction accumulator spring lock coupling. Remove and discard the O-ring seal.

-

During installation, install a new O-ring seal lubricated with PAG Refrigerant Compressor Oil (R-134a Systems) F7AZ-19589-DA (Motorcraft
YN-12-C), or equivalent meeting Ford specification WSH-M1C231-B.

9. Remove the screw.

10. Remove the suction accumulator.

INSTALLATION

1. To install, reverse the removal procedure.
2. Evacuate, leak test and charge the A/C system.