8. Release the auxiliary heater outlet hose clamp and disconnect the auxiliary heater outlet hose.
9. Remove the auxiliary evaporator outlet line fitting nut and disconnect the fitting.

-

To install, tighten to 8 Nm (71 lb-in).

10. Remove the auxiliary evaporator inlet line fitting nut and disconnect the fitting.

-

To install, tighten to 8 Nm (71 lb-in).

11. Remove the 2 floorpan bracket nuts.

-

To install, tighten to 3 Nm (27 lb-in).

Vehicles with power liftgate (PLG)

12. Disconnect the power liftgate (PLG) module electrical connector.
13. Remove the PLG module bolt.

-

To install, tighten to 9 Nm (80 lb-in).

14. Remove the PLG module and bracket.

All vehicles

15. Remove the 2 auxiliary duct pin-type retainers and detach the auxiliary ducts.
16. Disconnect the 2 auxiliary climate control housing electrical connectors.
17. Detach the auxiliary blower motor relay pin-type retainer(s).
18. Remove the 3 auxiliary climate control housing bolts.

-

To install, tighten to 6 Nm (53 lb-in).

19. Remove the auxiliary climate control housing.
20. To install, reverse the removal procedure.

-

Install new O-ring seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

21. Fill the engine coolant.
22. Evacuate, leak test and charge the refrigerant system.