COMPONENT TESTING PROCEDURE (Voltage Applied) Rear Blower Relay

Disconnect the ohmmeter; connect pins 3 and 1 to 12V DC power pin to ground. Measure voltage between pin 5 and pin 2. If the voltage is 12V,
continue with the test. If not, replace the relay.