Cooper (R56) L4-1.6L (N12) (2008)
Important!
Screws have different lengths.
Numbers: 4,6,10,12=28 mm.
Numbers: 2,3,5,7,8,11=21 mm.
Numbers: 1,9=16 mm.
First release screws uniformly in specified order and then remove.
Remove selector unit.
Installation:
Pay attention to installation location of cable holders and cables.
Important!
Under the selector unit at the end of the selector slide is the accumulator plunger (1) with spring.
Hold accumulator plunger (1) and spring firmly when removing selector unit.
Installation:
Moisten accumulator plunger and spring with ATF.
Install selector unit, accumulator plunger and spring simultaneously.