Cooper Convertible (R57) L4-1.6L (N12) (2009)
Release screw (2).
Installation Note:
Replace all sealing rings and moisten with refrigerant oil.
Grip refrigerant lines when tightening screws!
Tightening torque 64 53 1AZ See: Hose/Line HVAC/Specifications.
Release screws (1).
Installation Note:
Tightening torque 64 53 2AZ See: Hose/Line HVAC/Specifications.
Make sure brackets are seated correctly on condenser.
Lift out condenser (2).
After installation:
-
Evacuate and fill A/C system See: Service and Repair/Procedures/Drawing off, Evacuating and Filling A/C System (R 134a)