Release screw (2).

Installation Note:

Replace all sealing rings and moisten with refrigerant oil.
Grip refrigerant lines when tightening screws!
Tightening torque 64 53 1AZ See: Hose/Line HVAC/Specifications.

Release screws (1).

Installation Note:

Tightening torque 64 53 2AZ See: Hose/Line HVAC/Specifications.
Make sure brackets are seated correctly on condenser.

Lift out condenser (2).

After installation:

-

Evacuate and fill A/C system See: Service and Repair/Procedures/Drawing off, Evacuating and Filling A/C System (R 134a)