METHOD BY USING REFRIGERANT RECOVERY AND RE-CYCLING UNIT

Using the refrigerant recovery and recycling unit, refill the refrigerant.

NOTE:  Refer to that Refrigerant Recovery and Recycling Unit Instruction Manual for operation of the unit.

DISCHARGING SYSTEM

Use the refrigerant recovery unit to discharge refrigerant gas from the system.

NOTE:  Refer to that Refrigerant Recovery and Recycling Unit Instruction Manual for operation of the unit.

OIL REFILLING IN THE AIR CONDITIONING SYSTEM

Too little oil will provide inadequate compressor lubrication and cause a compressor failure. Too much oil will increase discharge air temperature.
When a compressor is installed at the factory, it contains 160 Cubic.cm (5.4 fl.oz.) of refrigerant oil. While the air conditioning system is in operation,
the oil is carried through the entire system by the refrigerant.
Some of this oil will be trapped and retained in various parts of the system.
When the following system components are charged, it is necessary to add oil to the system to replace the oil being removed with the component.

Compressor oil: SUN PAG 56

Quantity

Evaporator: 60 Cubic.cm (2.0 fl.oz.)
Condenser: 15 Cubic.cm (0.5 fl.oz.)
Suction hose: 10 Cubic.cm (0.3 fl.oz.)
Receiver: 10 Cubic.cm (0.3 fl.oz.)