mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 2766 > < Diagram Information and Instructions|Page 2764
Page 1
background image

Manifold Pressure/Vacuum Sensor: Testing and Inspection

OPERATION 

-

Manifold differential pressure switch converts the intake manifold plenum pressure to the voltage and inputs to the engine control module. Engine
control module confirms the operation of EGR system from this signal and, if there is any error in the EGR system, memorizes the diagnostic
trouble code.

-

5 V of power is supplied to the manifold differential pressure sensor from the engine control module and the sensor circuit ground is located in the
engine control module.

-

The manifold differential pressure sensor output voltage is proportioned to the intake manifold plenum pressure and sent to the engine control
module.

INSPECTION 

Diagram Information and Instructions|Page 2766 > < Diagram Information and Instructions|Page 2764