mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Knock Sensor > < Diagram Information and Instructions|Page 1962
Page 3
background image

(2) Measure resistance between terminals (5) and (6).

(3) Measure resistance while heating the sensor using a hair drier.
(4) If resistance does not decrease as heat increases or the resistance remains unchanged, replace the volume air flow sensor assembly.

Knock Sensor > < Diagram Information and Instructions|Page 1962