FREQUENCY TESTING PROCEDURES 

1.

Warm engine. Coolant temperature should be at: 85-95°C (185-205°F), with no electrical accessory loads on. Connect a Frequency counter
(HERTZ counter) between terminal 5 and 3 (do not remove the connector, instead insert a straight pin or needle from the back side of the
connector) of the Air Flow Sensor (AFS) connector.
Terminal 5: Sensor ground
Terminal 3: AFS output

2.

Measure the frequency across terminals 5 and 3. 

Standard Values 
25 to 50 Hz at 750 rpm
70 to 100 Hz at 2,000 rpm
Frequency increases as RPM increases