Diamante Sedan V6-2972cc 3.0L DOHC (1993)
Variable Induction Position Sensor: Description and Operation
Variable Induction Control Motor
Purpose
The sensor converts the induction control valve opening in degrees into a pulse signal which the ECM uses to calculate induction control valve
actuation.
Operation
The induction control valve position sensor receives both a 5 Volt power supply, and ground from the ECM.
A 5 Volt signal is applied from the ECM to the two output terminals of the sensor.
The sensor generates a pulse signal by opening and closing the ground circuit of the output terminals.