mitsubishi Workshop Repair Guides

Mitsubishi Diamante Sedan V6 30L DOHC Workshop Manuals

Starting System > < Electrical Specifications
Page 1
background image

Voltage Regulator: Mechanical Specifications
System Operating Voltage

System Operating Voltage 

Type

Battery Voltage Sensing (built in) 

   

  

 

Regulated Voltage

14.2-15.4 V at -4 deg F 

   

  

 

13.9-14.9 V at 68 deg F 

    

  

 

  

 

13.4-14.6 V at 140 deg F 

    

  

 

  

 

13.1 -14.5 V at 176 deg F 

    

  

 

  

 

Starting System > < Electrical Specifications