Diamante Sedan V6-3.5L SOHC (1999)
CAUTION: Make absolutely sure that no oil is adhering to the rubber ring of the thermostat. In addition, be careful not to fold over or scratch the
rubber ring when inserting.
>B< Radiator Lower Hose Connection
1. Insert each hose as far as the projection of the water outlet fitting or water inlet fitting.
2. Align the mating marks on the radiator hose and hose clamp, and then connect the radiator hose.