mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Symptom Related Diagnostic Procedures|Page 2399 > < Symptom Related Diagnostic Procedures|Page 2397
Page 3
background image

IDLE AIR CONTROL MOTOR (STEPPER MOTOR) CHECK

Checking the Operation Sound

1. Check that the engine coolant temperature is 20 °C (68 °F) or below.

NOTE: Disconnecting the engine coolant temperature sensor connector and connecting the harness-side of the connector to another engine
coolant temperature sensor that is at 200 °C (68 °F) or below is okay for this test.

2. Check that the operation sound of the stepper motor can be heard after the ignition is switched ON. (but without starting the motor.)
3. If the operation sound cannot be heard, check the stepper motor's activation circuit.

If the circuit is normal, it is probable that there is a malfunction of the stepper motor or engine control module.

Checking the Coil Resistance

1. Disconnect the idle air control motor connector and connect the test harness special tool MD998463.
2. Measure the resistance between terminal 2 (white clip of the special tool) and either terminal 1 (red clip) or terminal 3 (blue clip) of the connector

at the idle control motor side.

Standard value: 28 - 33 Ohms [at 20 °C (68 °F)]

If resistance is not within the standard value, replace the IAC motor.

3. Measure the resistance between terminal 5 (green clip of the special tool) and either terminal 6 (yellow clip) or terminal 4 (black clip) of the

connector at the idle control motor side.

Standard value: 28 - 33 Ohms [at 20 °C (68 °F)]

Operation check

1. Remove the throttle body.
2. Remove the stepper motor.
3. Connect the special tool MD998463 to the idle air control motor connector.

Symptom Related Diagnostic Procedures|Page 2399 > < Symptom Related Diagnostic Procedures|Page 2397