4. Measure the distance between the rear edge of the glass and the "C" pillar moulding at cross section K-K. This will give dimension "P".
Standard value:
(M)12.7 ± 1.0 mm (0.5 ± 0.039 in.) (parallel within 1.5 mm [0.059 in.])
(N)3.4 ± 1.0 mm (0.13 ± 0.039 in.)
(P)4.2 ± 1.0 mm (0.17 ± 0.039 in.)
5. Raise the rear glass fully (engine running), close the door until the rear corner of the door glass just contacts the door seal and measure the distance
between the rear edge of the opened door panel and the adjacent panel (rear fender) at the widest point (soft touch).
Standard value: 20 - 25 mm (0.78 - 0.98 in.) if weatherstrip is new.
Standard value: 15 - 20 mm (0.59 - 0.78 in.) if weatherstrip fitted for more than 7 days
6. Remove the belt line moulding and check the door glass stabilizer setting using a suitable gauge, while maintaining an inboard preload condition
on the top of the glass of 2 kg (4.4 lbs.) force (or sufficient force to ensure that the stabilizer block fibres are being compressed).
Standard value: