DIAGNOSTIC TABLE 

8. After inspection, disconnect the scan tool immediately after turning the ignition switch to OFF.

SOLENOID VALVE CHECK 

Measure the resistance between terminals.

Standard value:  1.O - 1.3 Ohms 

MOTOR OPERATION CHECK 

Connect the battery and check to be sure that the sound of the hydraulic unit motor operating can be heard.

CAUTION:  The battery power should not be applied for more than 1 second 