mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Starting and Charging > < Component Tests and General Diagnostics|Page 4384
Page 3
background image

FRONT SPEED SENSOR/REAR SPEED SENSOR INSTALLATION 

The clearance between the speed sensor and the rotor's toothed surface is not adjustable, but measure the distance between the sensor installation
surface and the rotor's toothed surface.

Standard value:  28.2 - 28.5 mm (1.11 - 1.12 in.) 

Starting and Charging > < Component Tests and General Diagnostics|Page 4384