Eclipse L4-1996cc 2.0L DOHC (1995)
REVOLUTION PICKUP SENSOR CHECK
Check the resistance value between terminals (1) and (2).
Standard value: 185 ohms when at 20°C (68°F)
HIGH PRESSURE RELIEF VALVE CHECK
The high pressure relief valve is a safety feature. It releases part of the refrigerant inside the system into the atmosphere when the high pressure level
exceeds 3,740 kPa (532 psi). Once the pressure inside the system has been reduced to 2,940 kPa (418 psi) or lower, the high pressure relief valve
closes to keep A/C system on.
(1) If a leak is detected at section A, replace the high pressure relief valve. The valve can be used unless there is a leak from that section.
(2) If a leak is detected at section B, retighten the valve. If the leak persists after that, replace the packing.
REASSEMBLY SERVICE POINTS
Shaft Seal Installation
Use a 21 mm (.83 in.) socket to install the shaft seal so that the 0-ring assembly side is facing the front housing.
Felt, Felt Holder Installation
After installing the felt in the felt holder, Install them to the front housing using a 14 mm (.55 in.) deep socket.
Front Housing Installation
(1) Apply compressor oil to the shaft.