mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Starting System > < Voltage Regulator|Specifications|Page 4028
Page 2
background image

If the voltage is not within the standard value, a malfunction of the voltage regulator or of the generator exists.

NOTE:  If the output current is 12.3 V, the terminal G may be grounded.

15. After the test, lower the engine speed to the idle speed.
16. Turn the ignition switch to the OFF position. 
17. Disconnect the negative battery cable. 
18. Disconnect the ammeter, voltmeter and tachometer. 
19. Connect the generator output wire to the generator "B" terminal.
20. Connect the negative battery cable.

Starting System > < Voltage Regulator|Specifications|Page 4028