Eclipse L4-2.4L (4G69) (2008)
2. Measure the resistance between combination meter connector terminals 3 and 4.
OK: 120 ± 20 ohms
Q: Does the resistance measure 120 ± 20 ohms?
YES : Go to Step 2.
NO : Replace the combination meter.
STEP 2. Check the terminator resistor inside the ECM [M/T] or PCM [A/T]. Measure the resistance at ECM [M/T] or PCM [A/T] connector
B-18.