mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2089 > < Initial Inspection and Diagnostic Overview|Page 2087
Page 84
background image

2. Measure the resistance between combination meter connector terminals 3 and 4.

OK: 120 ± 20 ohms

Q: Does the resistance measure 120 ± 20 ohms?

YES : Go to Step 2.

NO : Replace the combination meter.

STEP 2. Check the terminator resistor inside the ECM [M/T] or PCM [A/T]. Measure the resistance at ECM [M/T] or PCM [A/T] connector
B-18.

Initial Inspection and Diagnostic Overview|Page 2089 > < Initial Inspection and Diagnostic Overview|Page 2087