mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2582 > < Initial Inspection and Diagnostic Overview|Page 2580
Page 295
background image

2. Measure the voltage between terminal 21 and ground.

-

The measured value should be 12 volts (battery positive voltage).

Q: Does the measured voltage correspond with this range?

YES: Go to Step 8.

NO: Go to Step 6.

STEP 6. Check combination meter connector C-42 for damage.

Q: Is combination meter connector C-42 in good condition?

YES: Go to Step 7.

NO: Repair or replace the connector. Refer to Harness Connector Inspection. Check that the high-beam indicator light illuminates normally.