mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 6384 > < Initial Inspection and Diagnostic Overview|Page 6382
Page 90
background image

1. Operate scan tool MB991958 according to the procedure below to display "Pulse check."

a. Select "Interactive Diagnosis."
b. Select "System Select."
c. Select "SWS."
d. Select "Pulse Checking."

2. Check if scan tool MB991958 sounds or not.

Q: When the key reminder switch is operated, does scan tool MB991958 sound?

YES: Replace the ETACS-ECU. When the ETACS-ECU is replaced, register the encrypted code. Refer to Encrypted Code Registration Criteria
Table in Antitheft and Alarm Systems. The forgotten key prevention function should work normally.

NO: Refer to Inspection Procedure N-1 "ETACS-ECU does not receive any signal from the key reminder switch."

Inspection Procedure D-1

INSPECTION PROCEDURE D-1: Power Windows: Power windows do not work at all.

NOTE:  This troubleshooting procedure requires use of scan tool MB991958 and SWS monitor kit MB991813. For details on how to use the SWS
monitor, refer to "How to use SWS monitor."

Initial Inspection and Diagnostic Overview|Page 6384 > < Initial Inspection and Diagnostic Overview|Page 6382