INSPECTION PROCEDURE E-4: Keyless Entry System: The liftgate is not opened when the keyless entry transmitter "LIFTGATE" button is
operated.

Transmitter "LIFT GATE" Input Signal

CIRCUIT OPERATION

A receiver is incorporated in the ETACS-ECU. This receiver receives a lock or unlock signal from the transmitter.

TROUBLESHOOTING HINTS

-

The keyless entry transmitter may be defective

-

The ETACS-ECU may be defective

-

The wiring harness or connectors may have loose, corroded, or damaged terminals, or terminals pushed back in the connector

DIAGNOSIS

Required Special Tools:

-

MB991223: Harness Set

-

MB992006: Extra Fine Probe

-

MB991958: Scan Tool (MUT-III Sub Assembly)
-

MB991824: V.C.I.

-

MB991827: MUT-III USB Cable

-

MB991910: MUT-III Main Harness A

STEP 1. Check the operation of the central door locking system.

Check that the liftgate can be locked and unlocked when the central door locking system is operated.

Q: Does the liftgate work normally?

YES: Go to Step 2.

NO: Refer to Inspection Procedure C-2 "Some doors do not lock or unlock."

STEP 2. Check that the doors can be locked and unlocked by using the keyless entry transmitter.

Q: Can the doors be locked and unlocked normally when the keyless entry transmitter is operated?

YES: Go to Step 3.

NO: Refer to Inspection Procedure E-1 "Keyless entry system does not operate."

STEP 3. Check the input signal (by using the pulse check mode of the monitor).

Check input signals from the transmitter.

Initial Inspection and Diagnostic Overview|Page 6430 > < Initial Inspection and Diagnostic Overview|Page 6428