mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 6630 > < Initial Inspection and Diagnostic Overview|Page 6628
Page 336
background image

1. Operate scan tool MB991958 according to the procedure below to display "Pulse check."

a. Select "Interactive Diagnosis."
b. Select "System Select."
c. Select "SWS."
d. Select "Pulse Checking."

Q: Does scan tool MB991958 sound when the liftgate is opened?

YES: Go to Step 6.

NO: Refer to Inspection Procedure N-6 "ETACS-ECU does not receive any signal from the liftgate latch switch."

STEP 6. Replace the combination meter.

1. Replace the combination meter.
2. Check that the door ajar indicator light illuminates normally.

Q: Is the door ajar indicator light in good condition?

YES: No action is necessary and testing is complete.

NO: Replace the ETACS-ECU. When the ETACS-ECU is replaced, register the encrypted code. Refer to Encrypted Code Registration Criteria
Table in Antitheft and Alarm Systems. Check that the door ajar indicator light illuminates normally.

Inspection Procedure L-8

INSPECTION PROCEDURE L-8: Interior Light: The seat belt warning light does not illuminate or go out normally

NOTE:  This troubleshooting procedure requires the use of scan tool MB991958 and SWS monitor kit MB991813. For details on how to use the SWS
monitor, refer to "How to use SWS monitor."