CIRCUIT OPERATION

The ETACS-ECU operates the following functions or systems according to signal from the door lock actuator:

-

Central door locking system

-

Ignition key reminder tone alarm

-

Keyless entry system

-

Dome light <door lock actuator (LH)>

TECHNICAL DESCRIPTION (COMMENT)

If the signal is not normal, the functions or systems described in "CIRCUIT OPERATION" do not work normally.

TROUBLESHOOTING HINTS

-

The door lock actuator may be defective

-

The wiring harness or connectors may have loose, corroded, or damaged terminals, or terminals pushed back in the connector

-

The ETACS-ECU may be defective

DIAGNOSIS

Required Special Tools:

-

MB991223: Harness Set

-

MB992006: Extra Fine Probe

-

MB991958: Scan Tool (MUT-III Sub Assembly)
-

MB991824: V.C.I.

-

MB991827: MUT-III USB Cable

-

MB991910: MUT-III Main Harness A

STEP 1. Check the input signal (by using the pulse check mode of the monitor).

Check the input signals from the door lock actuators.

CAUTION:  To prevent damage to scan tool MB991958, always turn the ignition switch to the "LOCK" (OFF) position before connecting or
disconnecting scan tool MB991958.

1. Connect the scan tool MB991958. Refer to "How to connect SWS monitor."
2. Operate scan tool MB991958 according to the procedure below to display "Pulse check."

a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "Pulse Checking."

3. Check that scan tool MB991958 sounds.

Initial Inspection and Diagnostic Overview|Page 6687 > < Initial Inspection and Diagnostic Overview|Page 6685