Seat Heater: Testing and Inspection
Seatback Heater Check

SEATBACK HEATER CHECK

Measure the resistance between terminals.

Standard value: At room temperature 20° C (68° F) Approximately 4.51 ohms ± 5%

NOTE:  When the interior temperature rises 1° C (34° F), a measurement standard value increases 0.031 ohms. And when the interior temperature
drops 1° C (34° F), a measurement standard value decreases 0.031 ohms.