2. Disconnect joint connector (3) C-03, and measure the resistance at the wiring harness side of joint connector (3) C-03.

3. Measure the resistance between joint connector (3) terminal 4 (CAN_H) and body ground.

OK: 1 k ohms or more

4. Measure the resistance between joint connector (3) terminal 15 (CAN_L) and body ground.

OK: 1 k ohms or more

CAUTION:  Strictly observe the specified wiring harness repair procedure.

Q: Is the check result normal?

YES: Go to Step 4.

NO: Repair the wiring harness between joint connector (3) and the combination meter connector.

STEP 4. Check the CAN line between joint connector (3) and the ETACS-ECU connector for short to ground. Measure the resistance at joint
connector (3) C-03.

CAUTION:  Disconnect the negative battery terminal.

1. Disconnect the negative battery terminal.

Initial Inspection and Diagnostic Overview|Page 2874 > < Initial Inspection and Diagnostic Overview|Page 2872