Eclipse V6-3.8L (6G75) (2006)
5. If the tolerance level between the sensor output and the input value is within 4.9 kg (11 pounds), the screen for the accuracy check completion
is displayed, and if more than 4.9 kg (11 pounds), the screen for abnormal condition is displayed.
NOTE: When the screen for the accuracy check of 0 kg (0 pound) is displayed, go to step (9). If the abnormal condition is displayed, check
the seat installation condition. If the seat is improperly installed, install it properly and carry out the operation in step (4) again.
6. When the abnormal condition is displayed, press the OK button and go to the calibration screen. If the cancel button is pressed the screen
returns to step (4).