10. If the tolerance level between the sensor output and the input value is within 4.9 kg (11 pounds), the screen for the accuracy check completion

is displayed, and if more than 4.9 kg (11 pounds), the screen for abnormal condition is displayed.

NOTE:  If the abnormal condition is displayed, check the seat installation condition. If the seat is improperly installed, install it properly and
repeat from step (4).

11. When the abnormal condition is displayed, press the OK button and go to the calibration screen. Return to step (9) when the cancel button is

pressed.